Catalogue TRIONYX - page 8

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.
Flammable
cabinets
Corrosive
cabinets
Toxic cabinets
and multirisk
Pesticide
range
Fume hoods, filtering
cabinets - Ventilation
Containment
and Cans
Anti-fire quipments
and File cabinets
Showers and first-
aid quipments
REGULATIONS
FM(FaCtory MUTUAL)
: Offers worldwide industrial and commercial product certification and
testing services throught its business unit FM Approvals. Recognized and respected across the
globe, FM approvals certification assures customers that a product has been objectively tested and
conforms to the hightest national standards. The FM certification requires a fire-resistance of 10
minutes for Safety cabinets, according to the heating curve NFPA 251-1969.
European NORM EN 14470-1:
It is applicable for storage of flammable and highly flammable
chemicals in a laboratory. The flammables used in laboratories must be stored in one or several
safety cabinets which are fire resistant 15 (minimum required),30,60 or 90 minutes.
European NORM EN 14470-2:
It is applicable for storage of gas cylinders in laboratories. The
gas cylinders used in laboratories must be stored in one or several safety cabinets which are fire
resistant 15 (minimum required),30,60 or 90 minutes.
NF X 15-211 - Mai 2009 NORM:
The standard indicate on the ventilation and filtration efficiency,
as well as the Containment efficiency for the recirculatory fume hood designed for chemicals use
in laboratories.
EUROPEAN NORM EN 1869-1997:
This norm indicates that a fire blankets must be able to resist
to a heat 900°C done by a fresh fuel oil (such as edible soya bean oil or rapaseed oil). The electric
resistance must not be below 1 Ohm.
EUROPEAN NORM EN ISO 1182:
Indicates the test for the non flammables buiding materials
(Thermic insulation).
EuROPEAN NORM EN 15154-1 AND EN 15154-2:
This regulation concerns first aid equipment
and especially body showers and eye-washers, connected to water network.
NTFIRE017:
Swedish standard in as per themarket of cabinets to store documents and IT furnitures.
3 sorts of fire resistance : 30,60, and 90 minutes.
08/2015
EN
14470-1
NF
X 15-211
EN
1869-1997
ISO
1182
EN
15154-1 / 2
NT Fire
017
EN
14470-2
GHS
-
Globally Harmonized System of Classification and Labelling of Chemicals (only concers the
safety container of the chemical itself, do not apply to safety storage cabinets : is an internationally
agreed-upon system, created by the United Nations. It supersedes the relevant system of the
European Union,which has implemented the United Nations’GHS into EU law as the CLP Regulation
and United States Occupational Safety and Health Administration standards. Not to be confused
with ISO 7010 and ISO 3864.
I
SO 7010/ISO 3864
(Relates to the labelling affixed to the safety cabinets) :The ISO 7010 prescribes
the safety signs to be used in the context of accident prevention, fire fighting and information on
the risks of health’s damages.The shape and color of each safety signs and the design of the graphic
symbols conform to ISO 3864.
ISO
7010 / 3864
GHS
1,2,3,4,5,6,7 9,10,11,12,13,14,15,16,17,18,...136